The purpose of this article is to list fuses for common Fluke meters. 

mceclip0.png

  Current Input FUSE PART NUMBERS  
   
  Do not substitute other brands or types of fuses 
Current Input   
FUSES:  
   
0.05A/250V P/N 2002234 
125mA/250V P/N 686527  
315mA/1000V   P/N 2279339
0.44A/1000V P/N 943121 (O) or 203411 (BP1) or 203414 (BP5) 
500mA/250V P/N 838151 (O) or 871181 (BP5)  IR=1500A  
500mA/1000V P/N 1990695 (4 pack)
0.5A/750V P/N 1556096  
630mA/250V P/N 740670 (O) or 871173 (BP5)  IR=1500A   
1A/600V P/N 830828 (O) or 871207 (BP5)  IR=10kA  
2A/250V P/N 376582 (O) or 871178 (BP5)   IR=100A  
2A/600V P/N 747600 (O) or 871215 (BP5)  IR=10kA  
3A/600V P/N 475004 or 871202 (BP5)  
11A/1000V P/N 803293 (was P/N 943118) (O) or 203403 (BP1) or 203406 (BP5)  IR=20kA 
15A/600V P/N 892583 (BP1)  871223 (Qty 5)  IR=100kA   
20A/600V P/N 643684  IR=100kA  

Here is a historical list of common Fluke meters. 

21 F1=630mA/250V   F2=3A/600V
21-2 F1=630mA/250V   F2=15A/600V    R20 = 0.36 ohm fusible resistor (P/N 740662)
21-3 F1=630mA/250V   F2=11A/1000V    R20 = 0.36 ohm fusible resistor (P/N 740662)
23 F1=630mA/250V   F2=15A/600V (was 20A)   R20 = 0.36 ohm fusible resistor (P/N 740662)
23-2 F1=630mA/250V   F2=15A/600V    R20 = 0.36 ohm fusible resistor (P/N 740662)
23-3 F1=0.44A/1000V   F2=11A/1000V
25 F1=3A/600V   F2=630mA/250V   F3=15A/600V (was 20A in early units)
26-3 F1=0.44A/1000V   F2=11A/1000V
27 Check with Fluke
29-2 F1=1A/600V   F2=15A/600V
70-2, 70-3 No current input jacks, therefore does not use or need fuses
73 Check with Fluke
73-2 F2=15A/600V
73-3 F1=630mA/250V  F2=11A/1000V  R20 = 0.36 ohm fusible resistor (P/N 740662)
75 Check with Fluke
75-2 F1=630mA/250V  F2=15A/600V  R20 = 0.36 ohm fusible resistor P/N 740662
75-3 F1=630mA/250V  F2=11A/1000V  R20 = 0.36 ohm fusible resistor (P/N 740662)
76 F1=1A/600V  F2=15A/600V
77 Check with Fluke
77-2 F1=630mA/250V  F2=15A/600V  R20 = 0.36 ohm fusible resistor P/N 740662
77-3 F1=0.44A/1000V   F2=11A/1000V
77-4 F1=0.44A/1000V   F2=11A/1000V
78 F1=15A/600V
79-2 F1=1A/600V   F2=15A/600V
79-3 F1=0.44A/1000V   F2=11A/1000V
83, 85, 87 Check with Fluke
83-3, 85-3, 83-5 F1=0.44A/1000V  F2=11A/1000V
87-3, 87E-3 F1=0.44A/1000V  F2=11A/1000V
87-4 F1=0.44A/1000V  F2=11A/1000V
87-5, 87-5/E F1=0.44A/1000V  F2=11A/1000V
88 F1=1A/600V  F2=15A/600V
88-5 F1=0.44A/1000V  F2=11A/1000V
89-4 F1=0.44A/1000V  F2=11A/1000V
110 No current input jacks, therefore does not use or need fuses
111, 112 F1=11A/1000V
113, 114, 116 No current input jacks, therefore does not use or need fuses
115, 117 F1=11A/1000V
175, 177, 179 F1=0.44A/1000V  F2=11A/1000V
187, 189 F1=0.44A/1000V  F2=11A/1000V
287, 289 F1=0.44A/1000V  F2=11A/1000V
1577, 1587 F1=0.44A/1000V