Views:

HC40 (Hand Tight Connection. 40 MPa / 6000 psi) are the TEST port connection adapters on these models of pressure accessories:

  • CPS-40M-HC40
  • TST-40M-HC40
  • P5514B

Below is an image of CPS-40M-HC40 with 1/4 NPT-F adapter and analog gauge. The CPS-40M-HC40 is supplied with 9 adaptors in a case with o-rings: NPT (1/8, 1/4, 3/8 & 1/2) and BSP (1/8, 1/4, 3/8 & 1/2) and M14 x 1.5 (quantity 1 of each size adapter).  The full adapter kit with case is model PK-ADPTR-HC40 and is Fluke part number 5008258. The adapters come with an o-ring installed in them.

mceclip2.png 

Below is an image of TST-40M-HC40 with 6270A pressure controller and analog gauge as Device Under Test (DUT). The TST-40M-HC40 is supplied with 9 adaptors in a case with o-rings: NPT and BSP (1/8, 1/4, 3/8 & 1/2) and M14 x 1.5. The full adapter kit with case is model PK-ADPTR-HC40 and is Fluke part number 5008258. The adapters come with an o-ring installed in them.

mceclip1.png

Below is an image of P5514B with two of the five included adapters installed in the TEST ports. P5514B includes two 1/4 NPT adapters and one each of the 1/2 NPT, 1/4 BSP and 1/2 BSP adapters (and o-rings). 

   mceclip0.png

 

HC40 (Hand Tight Connection, 40 MPa / 6000 psi)

  • The TEST port has a female, swiveling collar that is M20 X 1.5 thread and an o-ring inside of it at the bottom. 
  • The 9 adaptors included with the CPS-40M-HC40 and TST-40M-HC40 are in a kit themselves with a storage case and o-rings. The full adapter kit with case is model PK-ADPTR-HC40 and is Fluke part number 5008258. The adapters come with an o-ring installed in them.
  • The adapters and test devices seal on the o-rings, PTFE tape and wrenches are not required.
  • Hand tight makes the seal in any rotational direction of the test device. The adaptor can be attached to the gauge, placed facing forward on the test port, and then the swiveling connection is turned to tighten the gauge

mceclip0.png     

1/4, 3/8, 1/2 and M14 x 1.5 adapters use any of these 3 o-rings:

  • 1785497, O-RING,NBR,BUNA-N,.070IN W,.239IN ID,70 DURO,BLACK,SIZE 2-010 (12 of these are included with the kit of adapters PK-ADPTR-HC40)
  • 3143327, O-RING,FKM,VITON,.070IN W,.239IN ID,70 DURO,RUST,SIZE -010 (7 are included in P5514B seal kit). However, these are not setup for sale. Order 1785497 instead.
  • 3867895, O-RING,EPDM,1.78MM W,6.07MM ID,70 DURO,BLACK,SIZE 2-010 (included with P5514B-EP and in P5514B-EP seal kit)

1/8 adapters use this o-ring

  • 1785510, O-RING,NBR,BUNA-N,.070IN W,.114IN ID,70 DURO,BLACK,SIZE 2-006.  (7 of these are included with the kit of adapters PK-ADPTR-HC40)
  • 3135369, O-RING,FKM,VITON,.070IN W,.114IN ID,75 DURO,BROWN,SIZE 2-006
  • 3865195, 54-703-10,O-RING VITON 1/4 X 1/16 X SEC (7 are included in P5514B seal kit). However, these are not setup for sale. Order 1785510 or 3135369 instead.

TEST port (M20x1.5) collar uses this o-ring

  • 4320521, O-RING,NBR,BUNA-N,.070IN W,.301IN ID,70 DURO,BLACK,SIZE -011
  • 3865174, 54-703-011,O-RING:VITON 5/16 X 1/16 XSEC (SIZE 011), included in P5514B-70M seal kit
  • 3865529, 54-705-011,O-RING:EPDM 5/16 X 1/16 XSEC (SIZE 011), included in P5514B-70M-EP seal kit

Also see the CPS-40M/100M instruction sheet here,
CPS-40M-HC40/CPS-100 Instructions

The TST-40M-HC40 Test Station and P5514B comparison test pump use the same TEST port, adapters and o-rings.

 

Here is a list of the available adapters if ordered one-by-one (not as a kit). Each includes the necessary o-ring. (The full adapter kit with case is model PK-ADPTR-HC40 and is Fluke part number 5008258. The adapters come with an o-ring installed in them.)

mceclip0.png

Part Number Description
5032871 ADPTR-HC40-1/2BSP FEMALE
5032867 ADPTR-HC40-3/8BSP FEMALE
5032859 ADPTR-HC40-1/4BSP FEMALE
5032844 ADPTR-HC40-1/8BSP FEMALE
5032914 ADPTR-HC40-1/2NPT FEMALE
5032906 ADPTR-HC40-3/8NPT FEMALE
5032898 ADPTR-HC40-1/4NPT FEMALE
5032880 ADPTR-HC40-1/8NPT FEMALE
5032923 ADPTR-HC40-M14 FEMALE